ID PG6500S GASOLINE GENERATOR MACHINE [GASOLINE] - 26320
ID PG6500S GASOLINE GENERATOR MACHINE [GASOLINE] - 26320

ID PG6500S GASOLINE GENERATOR MACHINE [GASOLINE] - 26320

Sale priceDhs. 1,760.00 Regular priceDhs. 2,000.00
SKU: 26320
Quantity:
Fallback Image Fallback Image Fallback Image
Only 1 unit left
Chat with us

Built Tough. Starts Easy. Powers Everything.

Ideal Power Tools PG6500S is a 5kW single-phase gasoline generator built for demanding environments. Powered by a 188FE 4-stroke OHV engine with Electric Start and AVR technology, it delivers stable, 240V / 50Hz power output with a generous 25-litre fuel tank — making it the go-to solution for construction sites, outdoor events, and emergency backup power across the UAE and beyond.

  • Rated & Maximum Power Output: Delivers a steady 5kW rated output with a 5.5kW maximum surge capacity, ensuring your heavy-duty tools, appliances, and equipment start and run without interruption — even under peak load conditions.
  • 188FE Single-Cylinder 4-Stroke OHV Engine: The heart of the PG6500S is the proven 188FE air-cooled engine, engineered for longevity and fuel efficiency. Its overhead valve (OHV) design reduces heat buildup, lowers oil consumption, and extends engine life — ideal for prolonged, continuous operation in hot climates like the UAE.
  • Dual Start System — Electric & Recoil: Equipped with both an electric self-start and a manual recoil backup, the PG6500S ensures you're never left without power. The electric start provides push-button convenience, while the recoil start serves as a reliable failsafe in any situation.
  • AVR (Automatic Voltage Regulation) Technology: The integrated AVR system continuously monitors and stabilises output voltage at 240V / 50Hz, protecting sensitive electronics, motors, and digital equipment from harmful power fluctuations and surges — a critical feature for professional and commercial use.
  • 25-Litre Fuel Tank & Compact Oil Capacity: The 25-litre (25,000ml) gasoline tank provides an extended runtime per fill, minimising downtime on long shifts. The 1.1-litre oil reservoir is sized for efficient lubrication cycles, and the unit weighs just 82kg net — manageable for transport with its fold-down handle and integrated wheels.
  • Digital Voltmeter & Dual 16A Sockets: The front-panel digital voltmeter gives operators instant, accurate voltage readings at a glance. Two 16A output sockets allow simultaneous connection of multiple devices, making it practical for multi-tool or multi-appliance setups on site.
  • CE Certified for Safety & Compliance: The PG6500S carries CE (Machine Test) certification, confirming it meets European safety, health, and environmental protection standards. It ships complete with a guide book, two 16A sockets, two wheels, and a fold-down handle — ready to deploy straight out of the box.
Key Features Perfect For
  • AVR Technology — Built-in Automatic Voltage Regulation for stable, spike-free power
  • Electric & Recoil Start — Dual-start system for effortless ignition in any condition
  • 188FE OHV Engine — Robust single-cylinder, 4-stroke engine for heavy-duty performance
  • 25L Fuel Tank — Extended run time with a large-capacity tank for uninterrupted operation
  • Digital Voltmeter — Real-time voltage monitoring for precise power management
  • Construction Sites — Powering tools and equipment in off-grid locations
  • Outdoor Events — Reliable electricity for lighting, sound, and catering setups
  • Emergency Backup — Home and business power continuity during outages
  • Remote Worksites — Portable power where the grid doesn't reach

General Purchase & Comparison Queries

What makes the PG6500S a better choice than a basic recoil-only generator?

The ID PG6500S goes well beyond a standard recoil-start generator by offering a dual-start system — both electric self-start and manual recoil — giving you the convenience of push-button ignition alongside a reliable backup. Add to that the built-in AVR (Automatic Voltage Regulation), a digital voltmeter, and a 5.5kW maximum power output, and you have a machine engineered for professional use, not just occasional home backup. The 188FE OHV engine also delivers superior fuel efficiency and longevity compared to basic side-valve engines found in entry-level units.

Is this generator suitable for both home backup and commercial/site use?

Yes. The PG6500S is designed to serve both environments effectively. For home backup, the 240V single-phase output and AVR protection make it safe to run household appliances, refrigerators, lighting, and air conditioning units. For commercial and construction site use, the 5kW rated / 5.5kW max output, heavy-duty 188FE engine, and large 25-litre fuel tank provide the sustained power and runtime needed for power tools, compressors, and site equipment. Its fold-down handle and wheel kit also make repositioning on site straightforward.

What fuel does the PG6500S use, and is it easy to source in the UAE?

The PG6500S runs on standard unleaded gasoline (petrol), which is widely and readily available at all fuel stations across the UAE. There is no need for specialist fuel blends or additives under normal operating conditions. The 25-litre tank capacity means fewer refuelling stops during long working days, and the engine is tuned to perform reliably in the warm ambient temperatures typical of the region.

Product-Specific and Usage Queries

What is the difference between the 5kW rated output and the 5.5kW maximum output?

The 5kW rated power output is the continuous, stable power the generator can safely deliver over extended periods of operation. The 5.5kW maximum output refers to the peak surge capacity — the short burst of additional power the generator can provide to handle the high start-up current draw of motors and compressors (known as inrush current). In practical terms, you should plan your connected load around the 5kW rated figure for sustained use, while the 5.5kW headroom ensures motors and pumps start reliably without tripping the generator.

How does the AVR technology protect my equipment?

AVR (Automatic Voltage Regulation) is an electronic system built into the generator's alternator that continuously monitors the output voltage and makes real-time corrections to keep it stable at 240V ± a tight tolerance. Without AVR, voltage can fluctuate as load changes — rising when load drops and falling when load increases. These fluctuations can damage sensitive electronics such as computers, variable-speed tools, inverter air conditioners, and medical equipment. The AVR in the PG6500S eliminates these spikes and dips, making it safe to connect a wide range of professional and domestic equipment.

Can I connect the PG6500S to my home's electrical panel (mains transfer)?

The PG6500S is supplied with two 16A output sockets for direct appliance connection. Connecting a generator directly to a home's fixed wiring or electrical panel requires a certified transfer switch installed by a licensed electrician — this is a legal and safety requirement in the UAE and most jurisdictions. Without a proper transfer switch, back-feeding electricity into the grid is extremely dangerous. We strongly recommend consulting a qualified electrician for any fixed installation. For portable, plug-in use across multiple appliances, the two 16A sockets are ready to use immediately.

Problem/Solution-Oriented Queries

The electric start isn't working — what should I do?

If the electric start fails to crank the engine, the most common cause is a discharged or faulty battery. First, check that the battery terminals are clean and securely connected. If the battery has been unused for an extended period, it may need recharging or replacement. Secondly, ensure the fuel valve is open and there is sufficient fuel in the 25-litre tank. Check that the choke is set correctly for a cold or warm start as per the guide book. If the electric start still fails, the manual recoil start is available as an immediate backup, allowing you to get power running while you troubleshoot the starter system.

My connected appliances are flickering or behaving erratically — is the generator faulty?

Flickering or erratic appliance behaviour is usually a sign of voltage instability, which can occur if the generator is overloaded beyond its 5kW rated capacity. Check the total wattage of all connected devices and ensure it does not exceed the rated output. The digital voltmeter on the control panel will show you the live output voltage — if it is reading significantly above or below 240V, reduce the load immediately. If the voltage remains unstable under normal load, the AVR unit may require inspection by a qualified technician. Also ensure the generator is on a level, stable surface and that the oil level is within the correct range, as low oil can trigger protective shutdowns that cause intermittent power loss.

The generator is consuming fuel faster than expected — what could be causing this?

Higher-than-expected fuel consumption on the PG6500S is typically linked to one of three factors. First, running at or near maximum load (5.5kW) will consume significantly more fuel than operating at 50–75% of rated capacity — the most fuel-efficient operating range for any generator. Second, a dirty or clogged air filter restricts airflow to the 188FE engine, causing it to run rich and burn more fuel; the air filter should be cleaned or replaced regularly, especially in dusty site environments. Third, old or degraded fuel can reduce combustion efficiency — always use fresh, clean unleaded gasoline and avoid leaving stale fuel in the tank during storage periods.